The FTE-5000 combines four functions for testing optical networks together in one unit. It brings together a -55dB ORL meter, power meter, laser source and video scope capability with IEC61300-3-35 method “B” Pass/Fail End face Grading Map (probe sold separately).
The FTE-5000 is a full featured ORL Loss Test Set. It has 4” super bright color touch screen display with large easy to read characters. It performs optical return loss measurements to -55db at up to three wavelengths and is an automated loss test set with dual or triple wave Light sources. The power meter uses an InGaAs detector which is calibrated at 850,1300, 1310, 1490, 1550 and 1625nm, with a dynamic range of -77dBm. These units are available in single, dual, triple or quad wavelength configurations and displays measurements up to three wavelengths at one time. In the Autotest mode, the master unit changes wavelengths at a fixed rate and informs the slave unit of the wavelength currently being measured. Use this method to test up to three wavelengths at a time and store the loss measurements for each of the lasers fired during the test. Up to 5000 tests may be stored and recalled via the unit’s USB port. Use TTI’s CertSoft PC application software for downloading stored data and organizing the information or use the Android Bluetooth virtual instrument application for remote operation.
The information from OTDR, LTS, ORL and video scope may be combined to offer a comprehensive report for all of your network testing needs.
The FTE-5000 also includes a video scope (probe sold separately). Use the video scope to ensure the integrity and cleanliness of the connectors being tested.
Use the modulation feature to perform fiber identification function. The power meter will identify modulated signals at 270, 1000 and 2000 Hz produced a modulate light source.
Ordering Information
FTE-5000-8513
LTS with 850/1300nm Light Source and Video Scope (Probe Sold Separately)
FTE-5000-1315
LTS with 1310/1550nm Light Source and Video Scope (Probe Sold Separately)
FTE-5000-345
LTS with 1310/1490/1550nm Light Source and Video Scope (Probe Sold Separately)
FTE-5000-QUAD
LTS with 850/1300/1310/1550nm Light Source (No Video Scope Capability)
General Specifications Display 4 in Color TFT Storage Locations 5000 Battery/Operating Time 4 AA Rechargeable NiMH / 6 hrs Power Requirements Wall Mount, Universal 100-240V 47-63 Hz 9 VDC Center Positive with, US, UK, Continental Europe, and Australian Plugs Operating Temperature Range -10 to 45 C Dimensions (w/o rubber boot ) 7.62” L x 3.88” W x 1.56” H (194mm L x 99mm W x 40mm H) Weight 0.52 Kg Accessories Provided FC, ST, SC adaptors for both Power Meter and Light Source, rubber boot, battery, power supply/charger, manual and software on CD and USB cable Power Meter Specifications Detector Type InGaAs Connector Type 2.5mm Interchangeable Dynamic Range +5 to -77dB (CATV - +25 to -57dB) Auto Test Range 0 to -40dB Calibrated Wavelengths 850,1300,1310,1490,1550,1625nm Units of Measurement dBm, dB, mW, µW and nW Power Measurement Uncertainty ± 0.18 dB under reference conditions, ± 0.25 dB from 0 to -65 dBm, ± 0.35 dB from 0 to +5 dBm and from -65 to -77 dBm Units of Measurement dBm, dB Resolution .01 dB Modulation Modes Detected CW, 270 Hz, 1000 Hz, 2000 Hz Light Source Specifications Fiber Type Single Mode, Multimode Wavelengths Available 850,1300,1310,1490,1550 and 625 nm ±20nm as Unit is Equipped Output Power 0 dBm, 1mw (-3dBm @ 1625nm) Output Stability ± .05 dB / 24 hrs @ constant temp,, ± .02 dB/C temperature coefficient Laser Safety Classification Class I Safety Per FDA/CDRH and IEC-825-1 Regulation Modulation Modes CW, 270 Hz, 1000 Hz, 2000 Hz Spectral Width <3nm typ. ORL Meter Optical Return Loss Dynamic Range 0-55 dB ORL Wavelengths SM Source Wavelengths Optical Return Loss Accuracy ± 1dB @ -40db reflection Resolution 0.01 dB
4 AA Rechargeable NiMH / 6 hrs
Wall Mount, Universal 100-240V 47-63 Hz 9 VDC Center Positive with, US, UK, Continental Europe, and Australian Plugs
Power Meter Specifications
Detector Type
InGaAs
Connector Type
2.5mm Interchangeable
Dynamic Range
+5 to -77dB (CATV - +25 to -57dB)
Auto Test Range
0 to -40dB
Calibrated Wavelengths
850,1300,1310,1490,1550,1625nm
Power Measurement Uncertainty
± 0.18 dB under reference conditions, ± 0.25 dB from 0 to -65 dBm, ± 0.35 dB from 0 to +5 dBm and from -65 to -77 dBm
Units of Measurement
dBm, dB
Resolution
.01 dB
Light Source Specifications
Fiber Type
Single Mode, Multimode
Wavelengths Available
850,1300,1310,1490,1550 and 625 nm ±20nm as Unit is Equipped
Output Power
0 dBm, 1mw (-3dBm @ 1625nm)
Laser Safety Classification
Class I Safety Per FDA/CDRH and IEC-825-1 Regulation
Modulation Modes
CW, 270 Hz, 1000 Hz, 2000 Hz